320/360KW CCS2 Double Gun DC Charging Equipment for Electric Vehicle Business Use
Product Description
Safety Function of DC EV Charger:
Charging gun temperature detection, over voltage protection, under voltage protection, overload protection, short circuit protection, grounding protection, over temperature protection, low temperature protection, insulation monitoring protection, polarity reverse protection, lightning protection, emergency stop protection, leakage protection.
Paramenters
| Model | SS-DC-320-Y-B-O-4 | SS-DC-360-Y-B-O-4 |
| Installation Method | Floor stand mounted | Floor stand mounted |
| Product size (mm) | 1000*900*1850mm | 1000*900*1850mm |
| Pacage size (mm) | 120X110X200 cm | 120X110X200 cm |
| G.W (kg) | 600kg | 600kg |
| INPUT | ||
| Voltage | 380VAC±15% | 380VAC±15% |
| Input frequency | 50/60Hz | 50/60Hz |
| Single Gun Output Current Range | CCS2: 0-250A | CCS2: 0-250A |
| OUTPUT | ||
| Voltage | DC200-1000V | DC200-1000V |
| Rated power KW | 320kW | 360kW |
| Charging cable length | 5m | 5m |
| Accuracy | Level 1.0 | Level 1.0 |
| Electrical Specification | ||
| Current Limit Protection Value | ≥110% | ≥110% |
| Voltage Stabilization Accuracy | ≤±0.5% | ≤±0.5% |
| Current Stabilization Accuracy | ≤±1% | ≤±1% |
| Ripple Ratio | ≤±0.5% | ≤±0.5% |
| Efficiency | ≥95% | ≥95% |
| Power Factor | ≥0.98 (above 50% load) | ≥0.98 (above 50% load) |
| Harmonic Content THD | ≤5% (above 50% load) | ≤5% (above 50% load) |
| RCD | / | |
| Functional Design | ||
| Human-computerinteraction | 7-inch bright colortouch screen,LED Indicator | 7-inch bright colortouch screen,LED Indicator |
| Charge mode | Automatic charging full / Fixed power /Fixed Amount / Fixed time | Automatic charging full / Fixed power /Fixed Amount / Fixed time |
| Charging method | NFC (Swipe to charge), scan QR code to charge | NFC (Swipe to charge), scan QR code to charge |
| Payment Methods | Swipe the card, scan QR code, Password | Swipe the card, scan QR code, Password |
| Networking methods | Ethernet, 4G | Ethernet, 4G |
| Executive standards | EN IEC 61851-1: 2019, EN 61851-23: 2014EN IEC 61851-21-2: 2021, EN IEC 61000-6-1: 2019 | EN IEC 61851-1: 2019, EN 61851-23: 2014EN IEC 61851-21-2: 2021, EN IEC 61000-6-1: 2019 |
| EVSE to Backend | OCPP1.6J | OCPP1.6J |
| Environmental Indicators | ||
| Working Temperature | -20℃ ~ +50℃ | -20℃ ~ +50℃ |
| Working Humidity | 5%~95% non-condensing frost | 5%~95% non-condensing frost |
| Working Altitude | <2000m | <2000m |
| Ingress Protection | IP54 | IP54 |
| Cooling Method | Air-cooled | Air-cooled |
| Noisy Control | ≤65dB | ≤65dB |
| MTBF | 17520 hours | 17520 hours |